Command Line Interface User’s Guide
Example
The following example configures the maximum storm control Broadcast rate at 900 Kbits/Sec on Ethernet port 1/
g5 of a FE port.
show ports storm-control
The show ports storm-control User/Privileged EXEC mode command displays the storm control configuration.
show ports storm-control [interface]
Parameters
interface — A valid Ethernet port. (Full syntax: unit/port)
Default Configuration
This command has no default configuration.
Command Modes
Privileged EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the storm control configuration.
Console(config)#
interface ethernet 1/g5
Console(config-if)#
port storm-control broadcast rate
900
Console#
show ports storm-control
Port State Rate [Kbits/Sec] Included
---- -------- ---------------- --------------------------------------
1/g1 Enabled 70 Broadcast, Multicast, Unknown Unicast
2/g1 Enabled 100 Broadcast
3/g1 Disabled 100 Broadcast