613-000709 Rev. CManagementModuleAT-MCF2000MInstallation Guide
Tables10
11PrefaceThis guide contains the installation instructions for the AT-MCF2000M Management Module for the AT-MCF2000 Media Converter Series. This prefa
Preface12Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Descriptio
AT-MCF2000M Management Module Installation Guide13Where to Find Web-based GuidesThe installation and user guides for all Allied Telesis products are a
Preface14Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support as well as sales and corporate inform
AT-MCF2000M Management Module Installation Guide15If the FTP server prompts you to log on, enter “anonymous” as the user name and your email address a
Preface16
17Chapter 1OverviewThis chapter contains the following sections: “Features” on page 18 “Front Panel” on page 20 “10/100/1000Base-T Management Port”
Chapter 1: Overview18FeaturesThe AT-MCF2000M unit is a management module for the media converter modules and chassis in the AT-MCF2000 Media Converter
AT-MCF2000M Management Module Installation Guide19Here are some of the management functions you can perform with the module and the AT-S97 Management
Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied
Chapter 1: Overview20Front PanelFigure 2 illustrates the front panel of the AT-MCF2000M Management Module.Figure 2. Front Panel of the AT-MCF2000M Man
AT-MCF2000M Management Module Installation Guide2110/100/1000Base-T Management PortThe 10/100/1000Base-T Management port is a standard Ethernet, Fast
Chapter 1: Overview22IEEE 802.3u compliant, the port can set its speed and duplex mode automatically with Auto-Negotiation, the default setting. Auto-
AT-MCF2000M Management Module Installation Guide23RS-232 Terminal PortThe management module can be managed locally through this port with a console or
Chapter 1: Overview24Stack PortYou can simplify the management of two or more AT-MCF2000 chassis by interconnecting the devices with the Stack port an
AT-MCF2000M Management Module Installation Guide25An example of a stack with four media converter chassis is illustrated in Figure 3.Figure 3. Example
Chapter 1: Overview26A chassis with the AT-MCF2000S Stacking Module must be managed through the stack because the module does not have a port for a lo
AT-MCF2000M Management Module Installation Guide27the management module is 0. The ID number for the AT-MCF2000S Stacking Module is set with DIP switch
Chapter 1: Overview28 The chassis with the AT-MCF2000M Management Module must be at one end of the stack. The other units are connected to the stack
AT-MCF2000M Management Module Installation Guide29Reset ButtonThe Reset button on the front panel of the management module initializes the AT-S97 Mana
3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-
Chapter 1: Overview30Figure 5. Pressing the Reset Button1203bAT-MCF2000MSTACK MANAGEME NTTERMINAL10/100/1000BASE-TRS-232RESETSDRDY BUSYMASTERPOWERBOOT
AT-MCF2000M Management Module Installation Guide31SD SlotThe SD slot accommodates a secure digital memory card. You might use a memory card in the fol
Chapter 1: Overview32Chassis ID JumperThe module has a jumper on the circuit board for setting the ID number of the module’s chassis. Refer to Figure
AT-MCF2000M Management Module Installation Guide33Module LEDsThe section describes the LEDs on the management module.GeneralStatus LEDsThe three LEDs
Chapter 1: Overview34RS-232TerminalPort LEDThe RS-232 Terminal port, used for local management of the chassis or stack, has a L/A (Link/Activity) LED.
AT-MCF2000M Management Module Installation Guide3510/100/1000Base-TManagementPort LEDsThe 10/100/1000Base-T Management port has a L/A (Link/Activity)
Chapter 1: Overview36The states of the Duplex-mode/Collisions LED on the Management port are described in Table 5.Stack PortLEDThe L/A (Link/Activity)
AT-MCF2000M Management Module Installation Guide37Secure DigitalMemoryCard SlotLEDThe secure digital memory card slot has one LED.Figure 11. SD Slot L
Chapter 1: Overview38
39Chapter 2InstallationThis chapter contains the following sections: “Reviewing Safety Precautions” on page 40 “Cable Requirements” on page 42 “Unp
4Translated Safety StatementsImportant: The indicates that a translation of the safety statement is available in a PDF document titled “Translated S
Chapter 2: Installation40Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the management module.
AT-MCF2000M Management Module Installation Guide41Warning: Only trained and qualified personnel are allowed to install or to replace this equipment.
Chapter 2: Installation42Cable Requirements10/100/1000Base-TManagementPortTable 8 lists the cable requirements for the 10/100/1000Base-T Management po
AT-MCF2000M Management Module Installation Guide43Stack Port Table 9 lists the cable requirements for the Stack port. For background information, refe
Chapter 2: Installation44Unpacking the AT-MCF2000M Management ModuleTo unpack the module, perform the following procedure:1. Remove all components fro
AT-MCF2000M Management Module Installation Guide45Setting the Chassis ID JumperThe management module has a jumper on the circuit board for setting the
Chapter 2: Installation46CautionThe management module is sensitive to and can be damaged by electrostatic discharge. Wear a grounding device and obser
AT-MCF2000M Management Module Installation Guide47Installing the Management ModuleCautionThe management module is sensitive to and can be damaged by e
Chapter 2: Installation48Figure 13. Removing the Blank Panel from the Management Slot2. Remove the insulator labelled “REMOVE BEFORE INSTALL” from the
AT-MCF2000M Management Module Installation Guide493. Align the edges of the module with the guides in the slot and carefully slide the module into the
5Preface ... 11Safety Symbols Used in this
Chapter 2: Installation504. Secure the management module to the chassis by tightening the two captive screws on the module with a cross-head screwdriv
AT-MCF2000M Management Module Installation Guide516. If the chassis will be part of a stack, Allied Telesis recommends affixing a label with the chass
Chapter 2: Installation52Cabling a Media Converter StackTo create a stack, connect the units together in a daisy chain topology using the Stack ports
AT-MCF2000M Management Module Installation Guide532. To connect two AT-MCF2000S Stacking Modules, connect either the Stack 1 or Stack 2 port on the st
Chapter 2: Installation543. To connect the last chassis of a stack with just one management module, you can use either port on the AT-MCF2000S Stackin
AT-MCF2000M Management Module Installation Guide55Verifying the InstallationThis procedure verifies the installation of the AT-MCF2000M Management Mod
Chapter 2: Installation56Starting a Local Management SessionTo start a local management session on the chassis or stack, perform the following procedu
AT-MCF2000M Management Module Installation Guide57NoteThe port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator progr
Chapter 2: Installation58chassis. For further information, refer to the AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide.
AT-MCF2000M Management Module Installation Guide59Removing the AT-MCF2000M Management ModuleThe AT-MCF2000M Management Module supports hot-swapping an
Contents6Starting a Local Management Session ...56Removing the AT-MCF2000M Management Mod
Chapter 2: Installation604. If you are not replacing the module, reinstall the blank panel over the management slot.NoteDo not leave a chassis slot op
AT-MCF2000M Management Module Installation Guide61Installing a Media Converter ModuleWhen a media converter module is installed into a chassis, the AT
Chapter 2: Installation62
63Chapter 3TroubleshootingThis chapter contains suggestions on how to troubleshoot the AT-MCF2000M Management Module if a problem occurs.Problem 1: Th
Chapter 3: Troubleshooting64Problem 3: A network cable is connected to the 10/100/1000Base-T Management port, but the port’s Link/Activity LED is off.
AT-MCF2000M Management Module Installation Guide65Problem 5: A twisted pair cable is connected to the Stack port on the management module, but the por
Chapter 3: Troubleshooting66
67Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D) 3.1 x 9.7 x 20.8 cm(1.2 x 3.8 x 8.2 in.)Weight 340 g (0.75 lb.)Envir
Appendix A: Technical Specifications68Safety and Electromagnetic Emissions CertificationsEMI (Emissions): FCC Class A, EN55022 Class A, EN61000-3-2, E
AT-MCF2000M Management Module Installation Guide69Table 11 lists the pin signals when the management port is operating at 1000 Mbps.Table 11. 10/100/1
7Figure 1: AT-MCF2000M Management Module... 18Figure 2: Front Panel of the AT-MCF2000M Management Modul
Appendix A: Technical Specifications70RS-232 Terminal Port PinoutsFigure 23 illustrates the pin layouts for the DIN-8 connector and port of the RS-232
Figures8
9Table 1: Safety Symbols ..................... 12Table 2: General Status LEDs ...