RS-232
TERMINAL PORT
STATUS
RESET
FAULT
POWER
10BASE-T / 100BASE-TX
FAST ETHERNET SWITCH
PORT ACTIVITY
1 3 5 7 9 11131517192123
2 4 6 8 10 12 14 16 18 20 22 24
LINK / RECEIVE
100M
10BASE-T / 100 BASE-TX
1X 3X 5X 7X
2X 4X 6X 8X
9X 11X 13X 15X 17X 19X 21X 23X
10X 12X 14X 16X 18X 20X 22X 24X
Auto-negotiating 10Base-T/100Base-TX Ports
Port Activity LEDs
RS232 Port
Power LED
Reset Button
Fault LED
Electrical Safety
IMPORTANT: When you see the !, go to the “Translated Safety Information
Booklet” for the translated safety statement in your language.
Elektrische Sicherheit
WICHTIG: Wenn Sie ! sehen, schlagen Sie in der „Broschüre mit übersetzten
Sicherheitsinformationen “ den übersetzten Sicherheitshinweis in Ihrer Sprache
nach. (German)
Elektrisk sikkerhed
VIGTIGT: Når De ser symbolet !, skal De slå op i "Brochure med oversatte
sikkerhedsadvarsler" for at finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
(Danish)
Elektrische veiligheid
BELANRIJK: Wanneer u het ! ziet, raadpleeg het “Boekje met vertaalde
veiligheidsinformatie” voor de vertaalde veiligheidsopmerking in uw eigen taal.
(Dutch)
Sécurité électrique
IMPORTANT: Lorsque vous voyez le symbole !, reportez-vous à la section « Livret
des traductions des informations de sécurité » pour consulter la traduction de ces
instructions dans votre langue. (French)
Sähköturvallisuus
TÄRKEÄÄ: Kun näet !-symbolin, katso omalle kielellesi käännettyä turvaohjetta
“Käännetyt turvaohjeet -vihkosesta“. (Finnish)
Sicurezza elettrica
IMPORTANTE: il simbolo !, indica di consultare l’“Opuscolo delle informazioni
sulla sicurezza tradotto” per gli avvisi di sicurezza tradotti nella propria lingua.
(Italian)
Elektrisk sikkerhet
VIKTIG: Når du ser !, går du til heftet “Oversatt sikkerhetsinformasjon” for å
finne den oversatte sikkerhetsinformasjonen på ønsket språk. (Norwegian)
Segurança Eléctrica
IMPORTANTE: Quando vir o símbolo !, consulte a “Folheto de Informação de
Segurança Traduzido” para ler a tradução da advertência de segurança no seu
idioma. (Portuguese)
Seguridad eléctrica
IMPORTANTE: Cuando vea el símbolo !, vaya al “Libreto de información de
seguridad traducida” para ver el mensaje de seguridad traducido a su idioma.
(Spanish)
Elsäkerhet
OBS! När du ser !, skall du gå till “Broschyr innehållande översatt
säkerhetsinformation” för att läsa det översatta säkerhetsmeddelandet på ditt språk.
(Swedish)
STANDARDS: This product meets the following standards
RADIATED ENERGY
U.S. Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with this
instruction guide, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or
the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital equipment meets all requirements of the Canadian Interference-
Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur
le matériel brouilleur du Canada.
RFI Emission EN55022 Class A ! 1
War nin g
In a domestic environment this product may cause radio
interference in which case the user may be required to take
adequate measures.
! 2
Immunity EN50082-1 ! 3
ELECTRICAL SAFETY TUV-EN60950, UL1950, CSA 950 ! 4
Laser EN60825
! 5
Class 1 Laser product.
!
6
At time of installation the Fiber Optic Lasers comply with FDA
Radiation Performance Standard 21CFR Subchapter J, applicable
at date of manufacture.
Warning Do not stare into the Laser beam.
!
7
ELECTRICAL NOTICES
War nin g
ELECTRICAL SHOCK HAZARD
To prevent ELECTRIC shock,
do not remove cover. No user-serviceable parts inside. This unit
contains HAZARDOUS VOLTAGES and should only be opened
by a trained and qualified technician. To avoid the possibility of
ELECTRIC SHOCK, disconnect electric power to the product
before connecting or disconnecting the LAN cables.
! 8
LIGHTNING DANGER
DANGER: DO NOT WORK on equipment or CABLES during periods of
LIGHTNING ACTIVITY. ! 9
ELECTRICAL-TYPE CLASS 1 EQUIPMENT
This equipment must be earthed. Power plug must be connected to a properly wired
earth ground socket outlet. An improperly wired socket outlet could place hazard-
ous voltages on accessible metal parts. ! 11
ELECTRICAL CORD NOTICE
Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of
<HAR> cordage molded IEC 320 connector on one end and on the other end a plug
approved by the country of end use. ! 12
OPERATING TEMPERATURE
Operating temperature is 0° C - 40° C. ! 14
POWER REQUIREMENT
100-120/200-240VAC ~ 50/60Hz, 1.0/0.5A
ALL COUNTRIES
Install product in accordance with local and National Electrical Codes. ! 15
Verifying Package Contents
Make sure your package contains the following items:
•
One AT-FS718 or AT-FS724 switch
•
This Quick Install Guide
•
Translated Safety Information Booklet
•
2 mounting brackets
•
6 flathead Phillips screws
•
Power cord (Americas, EC, and UK only)
Switch Overview
The switches described in this guide are standalone, unmanaged Fast
Ethernet switches for desktop and workgroup applications. They
implement direct high-speed server and backbone connections and
connectivity between the 10 Mbps and 100 Mbps segments. Full-duplex
operation on each 10Base-T/100Base-TX port provides up to 200 Mbps
of bandwidth per port to end stations, servers, routers, and other
switches.
Installing the Switch
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling.
! 13
1.
If desk-mounting the unit
, make sure that the switch is placed on a
level, secure desktop. Now skip to Step 6.
2.
If rack-mounting the unit,
remove all cables and power cord from
the switch (if previously attached).
3. Remove the snap-on plastic feet.
4. Attach the rack-mounting brackets to each side of the switch, using
the 6 flathead screws provided, as shown below.
5. Mount the switch in the rack.
6. Apply power to the unit as follows:
Caution
The power cord is used as a disconnect device. To de-energize
equipment, disconnect the power cord.
! 10
Attach the power cord to the unit and plug it in the power source.
Verify that the POWER LED lights green.
7. Attach the data cables. Verify that the LINK/RECEIVE LEDs light
green (see LED table).
R PORT
RS-232
TERMINAL PORT
STATUS
RESET
FAULT
POWER
For troubleshooting techniques, see
Chapter 3, Troubleshooting
in the
AT-FS718 and AT-FS724 Installation Guide
at
www.alliedtelesyn.com
.
The switch is now operational using the default port configuration.
Setting Up Your Terminal for Port Configuration or Diagnostics
1. Use a straight-through serial cable to connect your terminal to the
RS232 connector on the switch’s front panel.
2. Access your terminal’s emulator program and use the following
terminal settings:
VT100
emulation,
8
data bits, no parity,
1
stop
bit, 9600 baud.
3. Press
Return
.
You are now ready to configure the switch ports, run diagnostics or
download updated software using an XMODEM. For details, refer to
Chapter 2 in the
AT-FS718 and AT-FS724 Installation Guide
located at
www.alliedtelesyn.com
.
Table 1
Switch LEDs
LED Color State Description
POWER
(system)
Green On The switch is receiving power, voltage is
within the acceptable range, and the
power supply is working.
Off No power.
FAULT (system) Red On The switch is malfunctioning.
Flashing The switch is booting, running
diagnostics, writing image to FLASH,
transferring files via XMODEM.
Off Normal operation.
LINK /
RECEIVE
(port, top row)
Green On There is a physical link with a device.
Flashing The port is receiving packets.
Off No link.
100 M
(port, bottom
row)
Amber On The port is operating at 100 Mbps, or
manually configured to 100Base-TX.
Off The port is operating at 10 Mbps.
2345
Commentaires sur ces manuels