Allied-telesis AT-MR840TF Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel informatique Allied-telesis AT-MR840TF. Allied Telesis AT-MR840TF User Manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - AT-MR840TF

CentreCOM AT-MR840TF 8-Port Hub Installation Guide PN 613-10662-00 Rev. A MR840TF_Book Page i Tuesday, November 11, 1997 3:46 PM

Page 2

xElectrical Safety and Installation Requirements STANDARDIT : Tämä tuote on seuraavien standardien mukainen. SÄTEILYENERGIA Tämä kaupallinen tuote o

Page 3 - Requirements

xiAT-MR840TF Installation Guide ASENNUSSOHJEETHUOMAUTUS : Nämä mallit on suunniteltu käytettäviksi VAAKA-asennossa. PYSTYASENNUSTA EI SAA TEHDÄ ilma

Page 4

xiiElectrical Safety and Installation Requirements ELETTRICITÀ—REGOLAZIONE AUTOMATICA DELLA TENSIONE Questo prodotto regolerà automaticamente la tens

Page 5

xiiiAT-MR840TF Installation Guidebrukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kval

Page 6

xivElectrical Safety and Installation Requirements PADRÕES : Este produto atende aos seguintes padrões. ENERGIA IRRADIADA Este produto foi testado e

Page 7

AT-MR840TF Installation Guidexv INSTRUÇÕES DE INSTALAÇÃOCUIDADO : Estes modelos foram projetados para funcionar na posição HORIZONTAL. NÃO DEVE SER

Page 8

Electrical Safety and Installation RequirementsxviELECTRICO—AUTO-AJUSTE DE TENSIONEste producto se ajustará automáticamente a cualquier tensión entre

Page 9

AT-MR840TF Installation GuidexviiDetta är en “KLASS 1 LYSDIODPRODUKT”INSTALLATIONFARA FÖR BLIXTNEDSLAGFARA: ARBETA EJ på utrustningen eller kablarna

Page 10

MR840TF_Book Page xviii Tuesday, November 11, 1997 3:46 PM

Page 11

xixTable of ContentsElectrical Safety and Installation Requirements ... iiiChapter 1Product Description ...

Page 12

Copyright  1997 Allied Telesyn International Corp.All rights reserved. No part of this publication may be reproduced without prior written permissi

Page 13

Table of ContentsxxChapter 3Configurations ... 15Standalone

Page 14

1Chapter 1Product DescriptionOverviewThe AT-MR840TF is a 10Base-T /10Base-FL standalone, unmanaged hub that has eight UTP (RJ45) ports and one fiber o

Page 15

Product Description2Figure 2: AT-MR840TF (ST/SC) Back PanelsMajor FeaturesThe major features of the AT-MR840TF include the following:❑ 10Base-T/10Base

Page 16

AT-MR820TR Hub Installation Guide3Functional DescriptionThe AT-MR840TF hub incorporates the latest technologies, including a custom Application Specif

Page 17

Product Description4Jabber Lock-up ProtectionJabber lock-up protects the hub from being overrun with excessively long data packets by isolating segmen

Page 18

AT-MR820TR Hub Installation Guide5Physical DescriptionThe hub’s major components include the following:❑ LEDs (port, hub, network)❑ Eight Unshielded/S

Page 19 - Table of Contents

Product Description6Table 2 lists and defines the ports, hub, and network status LEDs.For detailed information concerning the Collision LED, see “Veri

Page 20

AT-MR820TR Hub Installation Guide7Figure 4: Port, Hub, and Network LEDs321321LINK OKRECEIVE10BASE-T NEIEEE 802.3 10BASE-T / 10BASE-FL MULTIPORT MICRO

Page 21 - Product Description

Product Description8UTP, Cascade, and Uplink PortsWhile the eight UTP ports can be used to directly connect to workstations in a standalone configurat

Page 22 - Major Features

AT-MR820TR Hub Installation Guide9MDI/MDI-X SwitchThe Media Dependent Interface/Media Dependent Interface Crossover (MDI/MDI-X) switch is a slide swit

Page 23 - Functional Description

iii Electrical Safety and Installation Requirements STANDARDS : This product meets the following standards.RFI Emission EN55022 Class A WARNING : I

Page 24 - Functional Block Diagram

Product Description10Power Requirements for Model TypesTable 4 lists the power requirements for the AT-MR840TF models.Table 4: Power Requirements for

Page 25 - Physical Description

11Chapter 2InstallationBefore You BeginBefore proceeding with the installation, please read “Electrical Safety and Installation Requirements” on page

Page 26

Installation12 NoteIf you are not using the UPLINK port (Port 8) for cascading to another hub, you may connect a standard 10Base-T cable to Port 8. S

Page 27 - HUB STATUS

AT-MR840TF Hub Installation Guide13Table 5 lists the MDI/MDI-X switch positions when using straight-through and crossover cable.Verifying Installation

Page 28

Installation14If the LINK OK LED does not light, there is no signal continuity.1. Check that the attached Data Terminal Equipment (DTE) is ON.2. Check

Page 29 - MDI/MDI-X Switch

15Chapter 3ConfigurationsThis chapter presents and illustrates the different types of configurations supported by this hub.❑ Standalone❑ Fiber uplink t

Page 30

Configurations16Fiber Optic Backbone Network ConfigurationThe most straightforward configuration is a hub attached to a fiber optic (10Base-FL) backbon

Page 31 - Installation

AT-MR840TF Installation Guide17Cascade ConfigurationPort 8, used in conjunction with the MDI/MDI-X switch, is the specified port that allows you to con

Page 32 - Making Cascading Connections

Configurations18The Four-Repeater RuleThe IEEE 802.3 standard provides general rules for 10Base-T cable length and network connections on single segme

Page 33 - Verifying Installation

19Appendix ATechnical SpecificationsThe AT-MR840TF SpecificationsPhysicalHeight 37.6 mm (1.55 in.)Width 332 mm (13 in.)Depth 112 mm (4.4 in.)Installatio

Page 34 - Verifying Collision LED

ivElectrical Safety and Installation Requirements SAFETYELECTRICAL NOTICESWARNING: ELECTRIC SHOCK HAZARDTo prevent ELECTRIC shock , do not remove co

Page 35 - 10BASE-T NETWORK PORTS

Technical Specifications20CertificationSafety CE CompliantUL 1950, CSA 22.2 No. 950, TUV EN60950, EN 60825Emission EMI/RFI FCC Class A, EN55022 Class

Page 36

AT-MR820TF Hub Installation Guide21Straight-through Cable WiringIf the twisted-pair link segment is to join two ports on a switch, and only one of the

Page 37 - Cascade Configuration

Technical Specifications2210Base-T/10Base-FL Network SpecificationsTable 10 provides an overview of the IEEE 802.3 specifications for 10Base-T/10Base-F

Page 38 - The Four-Repeater Rule

23Appendix BTechnical Support Fax OrderName__________________________________________________________________Company _________________________________

Page 39 - Technical Specifications

MR840TF_Book Page 24 Tuesday, November 11, 1997 3:46 PM

Page 40 - Certification

25Appendix CAT-MR840TF Installation Guide FeedbackPlease tell us what additional information you would like to see discussed in the guide. If there ar

Page 41 - Crossover Cable Wiring

MR840TF_Book Page 26 Tuesday, November 11, 1997 3:46 PM

Page 42 - Technical Specifications

27Appendix DWhere To Find UsFor Technical Support or ServiceLocation Phone FaxAmericasUnited States, Canada, Mexico, Central America, South America1 (

Page 43 - Technical Support Fax Order

Where To Find Us28AustraliaLindfield, NSWTel: (612) 416-0619, Fax: (612) 416-9764CanadaRexdale, OntarioTel: (416) 675-6738, Fax: (416) 675-0057Richmond

Page 44

vAT-MR840TF Installation Guide NORMEN : Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.Hochfrequenzstörung EN55022 Klasse A WARNU

Page 45 - Appendix C

viElectrical Safety and Installation Requirements VORSICHT Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang

Page 46

viiAT-MR840TF Installation Guide ELEKTRISK—KLASSE 1-UDSTYR DETTE UDSTYR KRÆVER JORDFORBINDELSE. Stikket skal være forbundet med en korrekt installer

Page 47 - Where To Find Us

viiiElectrical Safety and Installation Requirements INSTALLATIEGEVAAR VOOR BLIKSEMINSLAGGEVAAR: NIET aan toestellen of KABELS WERKEN bij BLIKSEM. WA

Page 48 - For Sales Information

ixAT-MR840TF Installation GuideSécurité électrique EN60950, UL1950, CSA 950Laser EN60825 SÉCURITÉINFORMATION SUR LES RISQUES ÉLECTRIQUESAVERTISSEMEN

Commentaires sur ces manuels

Pas de commentaire