Planning the Installation
30
AT-8316F and AT-8324 Switch Cabling Specifications
Table 2-1 contains the cabling specifications for the data ports on the
switches.
Note
To connect a workstation or server to a twisted pair port on an
AT-8324 switch, use a straight-through cable. To connect a hub,
router, or other switch to a twisted pair port on the AT-8324 switch,
use a crossover cable.
Table 2-1 Switch Cabling Specifications
Model Type of Cabling Maximum Distance
AT-8316F
(models MT, VF, and SC)
50/125 micron multimode or
62.5/125 micron multimode
Full-duplex:
2 kilometers (1.25 miles)
Half-duplex:
412 meters (1,351 feet)
AT-8324 10Base-T operation:
Category 3 or better
100Base-TX operation:
Category 5 or better
100 meters (328 feet)
100 meters (328 feet)