Removable Power Supply and Fan
12
5. Ensure there are no exposed cable strands.
6. Replace the cover. You must replace the transparent plastic terminal cover
before continuing.
7. Secure the supply cable to the rack framework or a similar object to ensure
that connections are isolated from any force applied to the cable.
8. Ensure the circuit breaker for the supply circuit and the Run/Standby
control on the PSU are off. Press and release the Run/Standby control so
that it is not pushed in (which is the Off position).
9. Connect the supply cable wires to the circuit breaker.
10. Turn on the PSU by pushing in the Run/Standby control.
11. Confirm that the switch is receiving power.
Check that at least one of the PSU LEDs on the front panel of the switch is
lit green. If no LEDs light, refer to the Hardware Reference for
troubleshooting information.