Allied-telesis AT-VIEW PLUS 2.4 DEVICE MANAGEMENT Manuel d'utilisateur Page 172

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 253
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 171
Allied Telesyn AT-VIEW PLUS
DEVICE MANAGEMENT
Rapier 48i
Device Manager LEDs for Rapier 48 and 48i
LED State Description
PWR
Green
Red
The switch is receiving power from the main power supply.
Main power supply is either off or has failed.
RPS
Green The switch is receiving power from the redundant power supply.
Red
Gray
RPS has failed.
RPS is not installed or RPS monitoring is disabled.
DUPLEX
Green
Orange
The port is operating at full duplex.
The port is operating at half duplex.
Note - The current firmware version does not allow AT-View Plus Device Manager to support the
Reset button.
Note - Please refer to Uplink Modules for the operations and behavior of the uplink modules
installed in this device.
Note - To turn RPS monitoring on or off on the switch, from the switch command line interface
enter the command SET SYSTEM RPSMONITOR={ON|OFF}. To see whether RPS monitoring is
PN 613-50507-00 Rev D Page 172 of 253
Vue de la page 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 252 253

Commentaires sur ces manuels

Pas de commentaire