Chapter 22: IGMP Snooping Commands
374 Section III: IGMP Snooping, MLD Snooping, and RRP Snooping
Examples
The following command activates IGMP snooping, sets the IGMP topology
to Multi-Host, and sets the timeout value to 120 seconds:
set ip igmp snoopingstatus=enabled hoststatus=multihost
timeout=120
The following command changes the topology to Single-Host:
set ip igmp hoststatus=singlehost
The following command disables IGMP snooping:
set ip igmp snoopingstatus=disabled
Equivalent Commands
disable igmpsnooping
For information, refer to “DISABLE IGMPSNOOPING” on page 370.
enable igmpsnooping
For information, refer to “ENABLE IGMPSNOOPING” on page 371.