AT-S63 Management Software Command Line Interface User’s Guide
Section I: Basic Operations 135
SET SWITCH PORT FILTERING
Syntax
set switch port=
port
[bcastfiltering=yes|no|on|off|true|false|enabled|
disabled]
[bcastegressfiltering=yes|no|on|off|true|false|enabled|
disabled]
[unkmcastfiltering=yes|no|on|off|true|false]
[unkmcastegressfiltering=yes|no|on|off|true|false]
[unkucastfiltering=yes|no|on|off|true|false]
[unkucastegressfiltering=yes|no|on|off|true|false]
Parameters
port Specifies the port you want to configure. You
can specify more than one port at a time. You
can specify the ports individually (for example,
5,7,22), as a range (for example, 18-23), or both
(for example, 1,5,14-22).
bcastfiltering Controls the ingress broadcast frame filter. The
options are:
yes, on, true, enabled The port discards all
ingress broadcast
frames. These options
are equivalent.
no, off, false, disabled The port forwards all
ingress broadcast
frames. This is the
default. These options
are equivalent.
bcastegressfiltering Controls the egress broadcast frame filter. The
options are:
yes, on, true, enabled The port discards all
egress broadcast
frames. These options
are equivalent.
no, off, false, disabled The port forwards all
egress broadcast
frames. This is the
default. These options
are equivalent.