AT-S60 Command Line User’s Guide
49
SET SYSTEM TEMPTHRESHOLD
Syntax
set system tempthreshold=temperature
Parameter
The parameter is defined below:
tempthreshold Specifies the maximum operating temperature for the
switch. The range is 0° to 90°C. The default is 80°C.
Description
This command sets the switch’s maximum operating temperature. If the
switch exceeds the temperature, the AT-S60 management software
sends a trap to the management workstations.
Example
The following command sets the switch’s maximum operating
temperature to 75°C:
set system tempthreshold=75