Allied-telesis AR700 Series Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
Features in 275-05 10
Version 275-05
C613-10473-00 REV D
Level 4
CR Module Level Description
AR400
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800
CR00010427
PPP,
IP Gateway
4 When a user entered the command reset ppp=instance to reset a PPP interface
with a dynamically allocated IP address, the router or switch produced an
erroneous log message.
This issue has been resolved.
YYY
- - - -YY-
CR00011995
BGP 4 To simplify displaying BGP memory usage, the command show /jointfilesconvert/1187528/bgp memlimit
/jointfilesconvert/1187528/bgp has been removed. Use the command show bgp memlimit scan instead.
Also, you can now display only the BGP backoff log messages by using either of
the following commands:
show log type=55 subtype=backoff
show log type=55 subtype=7
YYY
- - - -YY-
CR00012043
BGP 4 When a user entered conflicting values for BGP backoff thresholds (the backoff
and low parameters of the set /jointfilesconvert/1187528/bgp backoff command), the error message did
not adequately show the dependency between these two parameters.
This issue has been resolved. The error message now reads (for example):
Error (3103332): BACKOFF parameter value 90 too low; must be greater than
LOW parameter value 94.
YYY- - - -YY-