Allied Telesis Patch 89262-08 Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 38
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Patch 89262-09 For AT-8900 Series Switches 3
Patch 89262-09 for Software Release 2.6.2
C613-10402-00 REV I
There was an issue in DNS Relay that resulted in a memory leak. The leak
occurred when a response to a relayed DNS request contained an
authoritative nameserver or additional information and the DNS request
was forwarded to one of those servers. There was also an issue whereby
DNS queries handled by DNS Relay would sometime result is corrupt
entries in the DNS cache. These issues have been resolved.
Occasionally, if the switch was configured with an IPsec policy that allowed
all IPv6 ICMP packets matching types 133,134,135 and 136, a ping to the
switch might fail. This issue has been resolved.
ARP packets were not being classified into subnet-based VLANs, as subnet
association rules applied to IP packets only. This issue has been resolved,
and ARP packets are now classified into the subnet VLANs.
A switch reboot could occur when a large number of proxied connections
were rapidly established, for example, during a SYN attack. This issue has
been resolved.
A switch reboot could occur when ifAdminStatus was set todown” on
some PPPoE interfaces. This issue has been resolved.
When a global interface was dynamically assigned an IP address via DHCP
or PPP, NAT configurations with dynamic private interfaces
(interface=dyn-<dyn-int-name>) were not updated. This resulted in the
failure of sessions received on dynamic private interfaces because the global
IP address was invalid. This issue has been resolved.
If a traffic class, which had a large number of flowgroup and classifires
associated with it, was added to a port, then a reboot could occur. This issue
has been resolved.
The switch would sometimes add a route with it own IP address for the
NEXTHOP address. This issue has been resolved.
If IPv6 traffic was being passed through a switch with an IPv6 accelerator
card installed, the CPU could reach 100% after some variable time,
depending on the data rate. This issue has been resolved.
PCR: 40612 Module: IPG, DNS Relay Level: 2
PCR: 40622 Module: IP6 Level: 2
PCR: 40628 Module: VLAN Level: 2
PCR: 40629 Module: FW Level: 2
PCR: 40635 Module: PPP Level: 2
PCR: 40638 Module: Firewall Level: 2
PCR: 40640 Module: QOS Level: 2
PCR: 40646 Module: OSPF, IPG Level: 2
PCR: 40650 Module: SWMX Level: 2