Allied Telesis AT-FS232 Guide d'installation Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 74
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
Technical Specifications
38
Table 9 Fiber Optic Datalink
Table 10 Fiber Optic Loss Specification (Benchmark)
Model
Fiber
Type
1
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
Minimum
Power/Link
Budget
Minimum
Operating
Distance
2
2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds
the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end node.
Maximum
Operating
Distance
3
3. Distance is calculated based on ideal situations without any other loss factor.
AT-FS232 50/125 MMF 13.0 dB 0 2 km (1.25 mi)
62.5/125 MMF 16.8 dB 0 2 km (1.25 mi)
AT-FS232/1 9/125 SMF 16.0 dB 0 15 km (9.4 mi)
AT-FS232/2 9/125 SMF 30.0 dB 0 40 km (25 mi)
AT-FS232/3 9/125 SMF 34.0 dB 15 km (9.4 mi) 70 km (43.4 mi)
AT-FS232/4 9/125 SMF 37.0 dB 40 km (24.8 mi) 90 km (55.8 mi)
Fiber Type
1
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
Fiber Optic
Diameter
Optical
Wavelength
Typical Loss
Factor
Bandwidth
MMF 50/125 microns 1310 nm 1.00 dB/km 400 Mhz-km
62.5/125 microns 1310 nm 1.00 dB/km 500 Mhz-km
SMF 9/125 microns 1310 nm 0.40 dB/km N/A
Vue de la page 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 73 74

Commentaires sur ces manuels

Pas de commentaire