AT-MC101XLAT-MC102XLAT-MC103XLAT-MC103LHAT-MC104XLAT-MC104LHFast Ethernet Media ConvertersVersion 4Installation GuidePN 613-000235 Rev A
PrefacexContacting Allied TelesynThis section provides Allied Telesyn contact information for technical support as well as sales or corporate informat
1Chapter 1OverviewThe AT-MC10x Series Fast Ethernet Media Converters include the following models: AT-MC101XL AT-MC102XL AT-MC103XL AT-MC103LH AT
Chapter 1: Overview2The AT-MC10x Series media converters can be installed on a desktop or in an AT-MCR12 chassis, AT-WLMT-10 Wallmounting Bracket, or
AT-MC10x Series Media Converters Installation Guide3Figure 4 displays an AT-MC103LH Media Converter.Figure 4. AT-MC103LH Model - Front PanelFigure 5 d
Chapter 1: Overview4Figure 7 displays an AT-MC103LH Media Converter.Figure 7. AT-MC10x Series - Rear PanelTable 1 lists the maximum operating distance
AT-MC10x Series Media Converters Installation Guide5Table 2 lists the maximum operating distances for the AT-MC104XL and AT-MC104LH media converters.T
Chapter 1: Overview6Key FeaturesThe media converters have the following key features: LEDs for unit and port status 100Base-TX twisted pair port (al
AT-MC10x Series Media Converters Installation Guide7Auto MDI/MDI-X An RJ-45 twisted pair port on an 100 Mbps Ethernet network device can have one of t
Chapter 1: Overview8MissingLinkThe MissingLink feature enables the fiber optic ports on the media converter to pass the “Link” status of their connect
AT-MC10x Series Media Converters Installation Guide9In most configurations, you will want to leave the Auto-Negotiation button activated so the unit c
Copyright © 2005 Allied Telesyn, Inc.www.alliedtelesyn.comAll rights reserved. No part of this publication may be reproduced without prior written per
Chapter 1: Overview10NoteAfter a configuration change, you must reset the media converter by powering OFF then powering ON the unitOn the AT-MC101XL,
AT-MC10x Series Media Converters Installation Guide11Network TopologiesThe AT-MC10x Series Media Converters can be used in two different types of topo
Chapter 1: Overview12Back-to-Back TopologyFigure 10 illustrates two AT-MC103XL media converters in a back-to-back configuration.Figure 10. Back-to-Bac
13Chapter 2InstallationThis chapter contains the following installation procedures for the AT-MC10x Series media converters. “Reviewing Safety Precau
Chapter 2: Installation14Reviewing Safety PrecautionsPlease review the following safety guidelines before installing the media converter.NoteWhen you
AT-MC10x Series Media Converters Installation Guide15WarningClass I Equipment. This equipment must be earthed. The power plug must be connected to a p
Chapter 2: Installation16Selecting a Site for the Media ConverterObserve the following requirements when choosing a site for the AT-MC10x Series Media
AT-MC10x Series Media Converters Installation Guide17Planning the InstallationBe sure to observe the following guidelines when planning the installati
Chapter 2: Installation18Table 6. 100Base-FX Fiber Optic Port (Half-duplex)11. The total distance of all fiber lengths cannot exceed the limits stated
AT-MC10x Series Media Converters Installation Guide19Unpacking the Media ConverterTo unpack the AT-MC10x Series media converter, perform the following
iiiElectrical Safety and Emission Compliance StatementStandards: This product meets the following standards.U.S. Federal Communications CommissionDecl
Chapter 2: Installation20Installing the Media ConverterThe AT-MC10x Series media converters can be used on a desktop, mounted on a wall, or installed
AT-MC10x Series Media Converters Installation Guide21Installing a Media Converter in an AT-WLMT-010 Bracket WallmountingThe AT-WLMT-10, shown in Figur
Chapter 2: Installation22Installing a Media Converter in an AT-TRAY4 for RackmountingThe AT-TRAY4, shown in Figure 14, is a "shelf" style un
AT-MC10x Series Media Converters Installation Guide23Powering On and Cabling the Media ConverterTo apply power to an AT-MC10x Series media converter a
Chapter 2: Installation246. If you are installing an AT-MC104XL or AT-MC104LH, repeat Step 4 to cable the second fiber optic port.NoteEnd-nodes connec
AT-MC10x Series Media Converters Installation Guide25Warranty RegistrationWhen you finish installing the product, you should register your product by
27Chapter 3TroubleshootingFollow the guidelines below to test and troubleshoot the installation in the event a problem occurs.If the PWR LED is OFF, d
Chapter 3: Troubleshooting28If the LINK LED for the fiber optic port is OFF, do the following: Verify that the end-node connected to the port is ON a
AT-MC10x Series Media Converters Installation Guide29Loopback TestTo check hardware reliability of the media converter, perform the following procedur
Electrical Safety and Emission Compliance StatementivRFI Emissions FCC Part 15 Class B, EN55022 Class B, CISPR 22 Class B, C-TICKImmunity EN55024Elect
31Appendix ATechnical SpecificationsPhysicalDimensions: W x D x H10.5 cm x 9.5 cm x 2.5 cm(4.125 in x 3.75 in x 1.0 in)Weight: .27 kg (0.60 lbs)Temper
Appendix A: Technical Specifications32Agency CertificationsRFI Emissions FCC Part 15 Class B, EN55022 Class B, CISPR 22 Class B, C-TICKImmunity EN5502
AT-MC10x Series Media Converters Installation Guide33RJ-45 Twisted Pair Port PinoutsFigure 16 illustrates the pin layout to an RJ-45 connector and por
Appendix A: Technical Specifications34Fiber Optic Port SpecificationsTable 9. Fiber Optic TransmitterModelFiber Type11. MMF = Multimode Fiber / SMF =
AT-MC10x Series Media Converters Installation Guide35Table 12. Fiber Optic Loss Specifications (Benchmarks)Table 11. Fiber Optic DatalinkModelFiber Ty
37Appendix BCleaning Fiber Optic ConnectorsThis section describes how to clean fiber optic connections. The fiber optic connector consists of a fiber
Appendix B: Cleaning Fiber Optic Connectors38This appendix provides the following procedures: “Using a Cartridge-Type Cleaner” on page 38 “Using a S
AT-MC10x Series Media Converters Installation Guide392. Place the ferrule tip on the exposed cleaning surface and rub the ferrule in a downward direct
vContentsElectrical Safety and Emission Compliance Statement ...iiiPreface ...
Appendix B: Cleaning Fiber Optic Connectors40NoteDo not touch the end face of the ferrule in the connector.WarningDo not stare into the laser beam. 2
AT-MC10x Series Media Converters Installation Guide41To clean a recessed ferrule using a swab, perform the following procedure.1. Insert the swab into
43Appendix CTranslated Electrical, Safety, and Emission InformationImportant: This appendix contains multiple-language translations for the safety sta
Appendix C: Translated Electrical, Safety, and Emission Information44Laser Safety NoticesElectrical Safety Notices1 Warning: Class 1 Laser product.2 W
AT-MC10x Series Media Converters Installation Guide4511 Warning: As a safety precaution, install a circuit breaker with a minimum value of 20 Amps bet
Appendix C: Translated Electrical, Safety, and Emission Information4621 Warning: The power source for the gateway unit should be located near the unit
AT-MC10x Series Media Converters Installation Guide4731 Warning: Do not look directly at the fiber optic cable ends or inspect the cable ends with an
Appendix C: Translated Electrical, Safety, and Emission Information48Telecommunications Compliance Notices41 Warning: When using your telephone equipm
AT-MC10x Series Media Converters Installation Guide49LasersicherheitshinweiseElektrische Sicherheitshinweise1 Achtung: Laserprodukt der Klasse 1.2 Ach
ContentsviInstalling the Media Converter ... 20Using the Media Converter on a
Appendix C: Translated Electrical, Safety, and Emission Information5011 Achtung: Als Sicherheitsvorkehrung sollte ein Ьberlastschalter mit einem minim
AT-MC10x Series Media Converters Installation Guide5120 Vorsicht: Bei der Innenraummontage des Gateway-Gerдts ist darauf zu achten, dass es in einer s
Appendix C: Translated Electrical, Safety, and Emission Information5229 Zur zuverlдssigen Stromversorgung des Gerдts sollte ein dedizierter Stromkreis
AT-MC10x Series Media Converters Installation Guide53Telekommunikationskonformitдtshinweise41 Achtung: Bei der Verwendung Ihrer Telefonausrьstung soll
Appendix C: Translated Electrical, Safety, and Emission Information54Avisos de seguridad láserAvisos de seguridad elйctricas1Atenciуn: Producto lбser
AT-MC10x Series Media Converters Installation Guide5511 Atenciуn: Como medida de seguridad, instale un disyuntor con un valor mнnimo de 20 A entre el
Appendix C: Translated Electrical, Safety, and Emission Information5621 Atenciуn: La toma elйctrica de la unidad de puerta de enlace debe estar situad
AT-MC10x Series Media Converters Installation Guide5732 Atenciуn: Esta unidad puede tener mбs de un cable de alimentaciуn. Para reducir el peligro de
Appendix C: Translated Electrical, Safety, and Emission Information58Avisos de conformidad de telecomunicaciones41 Atenciуn: Cuando utilice su equipo
AT-MC10x Series Media Converters Installation Guide59Avis de sécurité laserAvis de sйcuritй йlectrique1 Avertissement: Produit laser de classe 1.2 Ave
viiPrefaceThis guide contains instructions on how to install an AT-MC10x Media Converter. How This Guide is OrganizedThis guide contains the following
Appendix C: Translated Electrical, Safety, and Emission Information6011 Avertissement: Par mesure de sйcuritй, installer un coupe-circuit d’une intens
AT-MC10x Series Media Converters Installation Guide6120 Attention: Si le pйriphйrique servant de passerelle est installй а l’intйrieur, s’assurer qu’i
Appendix C: Translated Electrical, Safety, and Emission Information6229 Utiliser des circuits d’alimentation ou des unitйs de conditionnement dйdiйs p
AT-MC10x Series Media Converters Installation Guide63Tйlйcommunications – Avis de conformitй41 Avertissement: Les prйcautions йlйmentaires de sйcuritй
Appendix C: Translated Electrical, Safety, and Emission Information64Indicazioni sulla sicurezza laserIndicazioni sulla sicurezza elettrica1 Avvertenz
AT-MC10x Series Media Converters Installation Guide6511 Avvertenza: Per precauzione, installare un salvavita con un valore minimo di 20 ampere tra l&a
Appendix C: Translated Electrical, Safety, and Emission Information6621 Avvertenza: La fonte di alimentazione dell'unitа gateway deve essere posi
AT-MC10x Series Media Converters Installation Guide6732 Avvertenza: Questa unitа potrebbe disporre di piщ cavi di alimentazione. Per ridurre il rischi
Appendix C: Translated Electrical, Safety, and Emission Information68Indicazioni per la conformitа con le norme sulle telecomunicazioni41 Avvertenza:
AT-MC10x Series Media Converters Installation Guide69Лазерная безопасностьЭлектрическая безопасность1 Внимание: лазерный продукт, класс 1.2 Внимание:
PrefaceviiiDocument ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that p
Appendix C: Translated Electrical, Safety, and Emission Information7010 Во всех странах: Инсталлируйте продукт в соответствии с национальными нормами
AT-MC10x Series Media Converters Installation Guide7120 Предостережение: Если шлюзовая установка инсталлируется в помещении, позаботьтесь, чтобы в пом
Appendix C: Translated Electrical, Safety, and Emission Information7230 Внимание: Корпус может быть тяжелым и поднять его может быть сложно. Allied Te
AT-MC10x Series Media Converters Installation Guide73Телекоммуникационное соответствие41 Внимание: При использовании телефонного оборудования, всегда
AT-MC10x Series Media Converters Installation GuideixWhere to Find Web-based GuidesThe installation and user guides for all Allied Telesyn products ar
Commentaires sur ces manuels