Hardware Reference 19
C613-03060-00 REV H
Mounting System
19 inch rack mounting
Front rack-mounting brackets incorporated in chassis. Mid or rear
mounting brackets optional
Expansion Bays
Two switch controller bays
•Four line card bays
Two power supply bays
One fan tray bay (compatible with the AT-SB4151 fan tray)
Alarm Relays
Two relays on rear panel
Normally open and normally closed contacts
Software configurable for a range of conditions
See “Alarm Relays and Monitoring” on page 32 for more information
Backplane Links and Bus Connections
A SwitchBlade chassis contains two controller bays each capable of
housing a switch controller card. See “Switching Performance and
Characteristics” on page 10 for more information.
33 MHz 64 bit PCI routing and control bus links all switch controller
and line card bays. This bus provides a high performance
communication channel between switch controller CPUs, and also
allows high speed routing between line cards that have WAN
interfaces.
Earth/Ground Point
An earth/ground point is provided on the chassis’s rear panel. This
point can be used to bond the chassis to earth/ground. Even if this point
is used, earth/ground leads of AC and DC power supplies must still be
connected.
AT-SB4161 & 2 SwitchBlade Power Supply Units
For guidelines on how many PSUs are required for a particular configuration,
see “How Many PSUs do You Need?” on page 33.
LEDs
Three LEDs indicate power supply status (input, output, and fan status)
For a complete list of LEDs and their functions, see “LEDs and What
They Mean” on page 47
Power Supply Specifications
Weight
3.6 kg