Allied-telesis AT-S24 Manuel d'utilisateur Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 164
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
AT-S24 Version 2.01 User’s Guide
141
Resetting the Statistics Counters
You reset statistics counters because:
The counters no longer reflect the current information.
For example, disabling a port to fix a problem does not reset its
counters. After the error clears and you manually re-enable the
port, you might want its statistics to accumulate from a fresh start.
Otherwise, the counters and the graph not only still reflect
information associated with the error condition; the counters
continue to increment from the wrong baseline.
As each frame type reaches the maximum of 2
32
(over 4 billion),
the statistics for that frame type resets to zero. Once this happens,
the counters and graph become inaccurately skewed.
To reset switch (system) counters, perform the following procedure:
1. From the Main Menu, select Ethernet Statistics.
2. Select Zero all statistics on the entire system.
Both Receive and Transmit counters and graphs are reset to zero.
Vue de la page 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 163 164

Commentaires sur ces manuels

Pas de commentaire