Chapter 4: Cabling and Powering on the Stack
62
Cabling the AT-StackXG Stacking Modules
Note
Allied Telesis recommends that during the initial installation you
power off the switches before you attach the stacking cables.
To connect the AT-StackXG/.5 Stacking Cables and the optional
AT-StackXG/1 Stacking Cable to the stacking modules, perform the
following procedure:
1. Remove the plastic protectors from the connectors on the
AT-StackXG/.5 Stacking Cable shipped with the stacking module.
Refer to Figure 24.
Figure 24. Removing the Plastic Protector
2. Starting with the top switch of the stack, connect the cable to either the
Stack Port 1 or Stack Port 2 on the stacking module and tighten the
two thumbscrews to secure it to the module.
Figure 25. Connecting the AT-StackXG/.5 Stacking Cable
1244
1245
A
T
-LX44CPUCVR
AT-StackXG
Stack Po
r
t 1
Stack Po
r
t 2