c. Strip the three wires in the cable tray coming from the DC input
power source to 8 millimeters
± 1 millimeters (0.31 inches ± 0.039
inches) using a 14-gauge wire-stripping tool.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation. ! 17
Figure 8 Stripped Wire
d. Connect the frame ground wire to the terminal marked with the
ground symbol by inserting the wire into the terminal block and
tightening the connection with a flathead screwdriver. See Figure 9.
Warning
When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last. ! 18
Figure 9 Connecting the Stripped Wire
8 mm ± 1 mm
(0.31 in ± 0.039 in)
PWR 2 PWR 1
PBM02
Management
MDI-X
MDI
LNK
STATUS
PWR
RESET
RS-232 Terminal 10Base-T
PBPWRDC
FOR CENTRALIZED DC
POWER CONNECTION,
INSTALL ONLY IN A
RESTRICTED AREA
36-60VDC , 1.0A
DC INPUT
36-60VDC , 1.0A
DC INPUT
Vue de la page 21