Allied-telesis AT-LMC10ST Manuel d'utilisateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
AT-LMC10SC and AT-LMC10ST Installation Guide
19
Fiber Optic Loss Specifications (Benchmarks)
Table 7 Fiber Optic Datalink
Model Fiber
Type
1
Minimum
Power /
Link
Budget
Average
Signal
Loss
Minimum
Distance
Spec.
2
Maximum
Distance
Spec.
AT-LMC10SC
and
AT-LMC10ST
50/125
MMF
13.00 dB 18.70 dB 0 2 km
(1.2 mi)
62.5/125
MMF
16.80 dB 22.50 dB 0 2 km
(1.2 mi)
1. MMF = Multimode Fiber
2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds
the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end-node.
Fiber Type
1
1. MMF = Multimode Fiber
Fiber Optic
Diameter
(microns)
Optical
Wavelength
Typical
Loss
Factor
(dB/km)
Worst Case
Loss Factor
(dB/km)
Bandwidt
h (Mhz-
km)
MMF 50/125 850 nm 3.00 3.50 400
50/125 1310 nm 1.00 1.50 400
62.5/125 850 nm 3.00 3.75 200
62.5/125 1310 nm 1.00 1.50 500
100/140 850 nm 4.00 4.00 100
Vue de la page 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 43 44

Commentaires sur ces manuels

Pas de commentaire