Chapter 6: Configuring the Media Converter Line Cards
214
Figure 89. SFP Information Window
SFP Information
Slot 4: Port A
Serial ID Number
Vendor name (OUI) ATI
Vendor IEEE Company ID 000
Vendor part number AT-SPLX10
Vendor revision number A
Vendor serial number A03236R075100037
Vendor date code 07122301
ATI Model
Digital Diagnostics Monitoring Information
Temperature - Celcius
Real Time 55.2500
Alarm Range (High, Low) (100.0000 , -40.0000)
Warning Range (High, Low) (95.0000 , -30.0000)
Supply Voltage- V
Real Time 3.2024
Alarm Range (High, Low) (3.4650 , 3.1350)
Warning Range (High, Low) (3.4000 , 3.2000)
Tx Bias Current - mA
Real Time 31.7600
Alarm Range (High, Low) (80.9280 , 10.4640)
Warning Range (High, Low) (70.9280 , 20.4640)
Tx Optical Power - mW
Real Time 0.2388
Alarm Range (High, Low) (0.4784 , 0.1202)
Warning Range (High, Low) (0.3800 , 0.1513)
Rx Received Power - mW
Real Time 0.0000
Alarm Range (High, Low) (1.0000 , 0.0079)
Warning Range (High, Low) (0.7943 , 0.0126)