AT-8202 ATM Uplink User’s Guide
1-13
Note
You must enter a VCI value when configuring a PVC connection type.
Additionally, make sure the PVC number is identical on all
FORMULA 8200 switches.
3. Enter
6 for VCI value configuration at the prompt.
4. Enter
501 as the VCI value when prompted.
/ATM/CONFIG/CREATE >PTOP 1
PTOP Configuration
1. PTOP Index: 1
2. PTOP Description (Optional): PTOP Instance 1
3. Admin Status(ENABLE(a),DISABLE(b): ENABLED
4. Encapsulation Type:(RFC1483(a),Proprietary RFC1483
5. Connection Type (PVC(a), (SVC(b): PVC
6. VCI value (Reqd if PVC):
7. Destination ATM Address (reqd if SVC):
Enter Selection, 0 to save the Modification or ‘q’ to Quit: 0
/Enter VCI value: 501
PTOP Configuration
1. PTOP Index: 1
2. PTOP Description (Optional): PTOP Instance 1
3. Admin Status(ENABLE(a),DISABLE(b): ENABLED
4. Encapsulation Type:(RFC1483(a),Proprietary RFC1483
5. Connection Type (PVC(a), (SVC(b): PVC
6. VCI value (Reqd if PVC): 501
7. Destination ATM Address (reqd if SVC):
Enter Selection, 0 to save the Modification or ‘q’ to Quit: 0
New VCI value