Allied Telesis AT-8648T/2SP Spécifications

Naviguer en ligne ou télécharger Spécifications pour Commutateurs de réseau Allied Telesis AT-8648T/2SP. Allied Telesis AT-8648T/2SP Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Hardware Reference

AT-8600 Series SwitchHardware ReferenceAT-8624T/2MAT-8624PoEAT-8648T/2SP

Page 2

10 AT-8600 SeriesC613-03080-00 REV GAT-A46 ExpansionModule LEDsAT-A47 ExpansionModule LEDsAT-A65 ExpansionModule LEDsLED State DescriptionLINK 10 Gree

Page 3 - Contents

Hardware Reference 11C613-03080-00 REV GExpansion OptionsExpansion modules increase switching capacity by providing two extra ports and by allowing sw

Page 4 - Hardware Description

12 AT-8600 SeriesC613-03080-00 REV GSwitch Start-UpWhen the switch starts up following a power cycle or an operator-initiated reboot (using the reset

Page 5 - Hardware Reference 5

Hardware Reference 13C613-03080-00 REV GRegular output The following messages are an example of output from the switch.Types of messages The following

Page 6 - AT-8648T/2SP Model

14 AT-8600 SeriesC613-03080-00 REV GFAIL: BBR test. Error address = locationBBR size/location test failed at the given location. The test at this loca

Page 7 - Implementing PoE

Hardware Reference 15C613-03080-00 REV GPortsThis section explains pin assignments for the following: RS-232 Terminal Port (ASYN0) RJ-45 PortsRS-232

Page 8 - AT-8624PoE switch

16 AT-8600 SeriesC613-03080-00 REV GRJ-45 PortsFor 10BASE-T/100BASE-TX connections, a twisted pair cable must be used. Each pair is identified by two

Page 9

Hardware Reference 17C613-03080-00 REV GFor 1000BASE-T RJ-45 cables, all four pairs are used and the cable is wired in a straight-through configuratio

Page 10 - C613-03080-00 REV G

18 AT-8600 SeriesC613-03080-00 REV GAT-8624PoE pin layout For the AT-8624 PoE switch, the pin layout is different. The molex connector has 15 power pi

Page 11 - Expansion Options

Hardware Reference 19C613-03080-00 REV GCablesThis section describes how to make cables for connecting switch interfaces to networks, terminals, and p

Page 12 - Switch Start-Up

AT-8600 Series Hardware ReferenceDocument Number C613-03080-00 REV G© 2006-2008 Allied Telesis Inc. All rights reserved. No part of this publication m

Page 13 - AlliedWare

20 AT-8600 SeriesC613-03080-00 REV GThe following figure shows the pin wiring diagram for a DCE RS-232 Terminal Port (DB9 female connector) male to ma

Page 14

Hardware Reference 21C613-03080-00 REV GCable GuidelinesThe following table lists port, connector, and cable combinations for each model.1. Refer to t

Page 15 - RS-232 Terminal Port (ASYN0)

22 AT-8600 SeriesC613-03080-00 REV GEnter a path name in the "Restrict to directory" field to prevent unauthorised access to private directo

Page 16 - RJ-45 Ports

Hardware Reference 23C613-03080-00 REV G2. In the Connection Description dialog box:• Enter a name for the connection, such as Admin.• Select an icon

Page 17 - Redundant Power Supply (RPS)

24 AT-8600 SeriesC613-03080-00 REV G4. In the COMn Properties dialog box, set port parameters as follows, and click the OK button.5. From the main Hyp

Page 18

Hardware Reference 25C613-03080-00 REV G6. Click ASCII Setup to display the ASCII Setup dialog box, and ensure the following options are not selected:

Page 19 - Terminal and Modem Cables

26 AT-8600 SeriesC613-03080-00 REV G10/100 Ethernet LAN Port TestsA loopback plug is required to run the first part of the Ethernet LAN test. See “Tes

Page 20 - DB9 Male Pin View

Hardware Reference 27C613-03080-00 REV GTesting Switch InterfacesLoopback plugs are used in conjunction with Test Facility software to test the physic

Page 21 - Using AT-TFTP Server

28 AT-8600 SeriesC613-03080-00 REV GCommon Problems and SolutionsPower LED is off If the power LED is off, it may indicate the following: a loose pow

Page 22 - Hyperterminal

Hardware Reference 29C613-03080-00 REV GIf you cannot access the switch’s software because of a faulty RS-232 Terminal Port connection, you can still

Page 23 - Hardware Reference 23

Hardware Reference 3C613-03080-00 REV GContentsModels Covered by this Document ... 4H

Page 24 - 24 AT-8600 Series

30 AT-8600 SeriesC613-03080-00 REV G4. To browse PDF documents, use any of the following to page through a document:• toolbar buttons, such as the Nex

Page 25 - Test Facility

4 AT-8600 SeriesC613-03080-00 REV GModels Covered by this DocumentThis Hardware Reference includes information on the following models: AT-8624T/2M 2

Page 26

Hardware Reference 5C613-03080-00 REV GPower Supply Unit Universal 100/240 VAC 50/60 Hz input Redundant DC Power connectionSwitching core Advance

Page 27 - Troubleshooting

6 AT-8600 SeriesC613-03080-00 REV GAT-8624T/2M Model• 24-port 10BASE-T/100BASE-TX (RJ-45 connectors)• Two expansion module bays• Auto-negotiating adva

Page 28 - Common Problems and Solutions

Hardware Reference 7C613-03080-00 REV GImplementing PoEThe IEEE 802.3af standard, which is the IEEE standard for PoE, describes two methods for implem

Page 29 - For More Information

8 AT-8600 SeriesC613-03080-00 REV GAT-8624T/2M switchLink and Mode LEDsAT-8624PoE switchLink and Mode LEDsLED State DescriptionLINK OFF There is no li

Page 30 - 30 AT-8600 Series

Hardware Reference 9C613-03080-00 REV GAT-8648T/2SP switchLink and Mode LEDsAT-8648T/2SP switch10/100/1000Base-Tand SFP LEDsAT-A45/xx SeriesExpansion