Allied-telesis x900 Series Switch and SwitchBlade x908 Manuel d'utilisateur Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 49
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
x900 Series Switch and SwitchBlade
®
x908
22
PWR05
LEDs
The following table describes LEDs on the PWR05 power supply unit for the
SwitchBlade x908.
LED State Description
~
IN
Green AC input voltage is within 90-264VAC, 47-63Hz.
Off AC input voltage is outside the acceptable range.
OUT
Green DC output voltage is within 12V +/- 10%.
Off DC output voltage is outside the acceptable range.
FAULT
Red A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70ºC (158ºF).
Off No fault conditions detected.