Allied-telesis AT-VIEW PLUS 2.4 DEVICE MANAGER Manuel d'utilisateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 119
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
Allied Telesyn AT-VIEW PLUS
DEVICE MANAGER
Undersize Packets
Oversize Packets
Fragment Packets
Jabber Packets
Custom
Shows all items plus Received Bytes but without Utilization.
Note - Items calculated by AT-View Plus Device Manager always have the descriptive title
(not the variable name) because they have no related MIB variables.
7.2.2 Management Information Area
At the bottom of RMON Statistics window, the following information is always displayed.
PortX: yyy Mbps
X is the port number of the selected port. yyy is the speed of the port.
Polling Interval: yyy sec
yyy is the polling interval in seconds.
In Polling / Polling Stopped
Status of polling. "In Polling" or "Polling Stopped".
Absolute Value / Per Sample / Per Second
Indicates how data is displayed.
Index
Value of etherStatsIndex of the RMON Statistics group.
Data Source
Value of etherStatsDataSource of the RMON Statistics group.
Owner
Value of etherStatsOwner of the RMON Statistics group.
Status
Value of etherStatsStatus of the RMON Statistics group.
7.2.3 Entry Tab
In the Entry tab, you can select and control the table entry displayed. Data collected by the selected
entry is shown in the Table, Plot Chart and Pie Chart tabs. By default, the entry with the lowest
index number is selected. In this tab, you can also add, remove or edit the entries.