Chapter 9: SNMPv3
172
8. Enter a value that you configured with the View Name parameter in the
SNMPv3 View Table.
A Read View Name allows the users assigned to this Group Name to
view the information specified by the View Table entry. This value
does not need to be unique.
The following prompt is displayed:
Enter Write View Name:
9. Enter a value that you configured with the View Name parameter in the
SNMPv3 View Table.
A Write View Name allows the users assigned to this Security Group
to write, or modify, the information in the specified View Table. This
value does not need to be unique.
The following prompt is displayed:
Enter Notify View Name:
10. Enter a value that you configured with the View Name parameter in the
SNMPv3 View Table.
A Notify View Name allows the users assigned to this Group Name to
send traps permitted in the specified View. This value does not need to
be unique.
The following prompt is displayed:
Enter Storage Type [V-Volatile, N-NonVolatile]:
11. Select one of the following storage types for this table entry:
V-Volatile
Select this storage type if you do not want the ability to save an entry in
the SNMPv3 Access Table to the configuration file.
N-NonVolatile
Select this storage type if you want the ability to save an entry in the
SNMPv3 Access Table to the configuration file. Allied Telesis
recommends this storage type.
The following prompt is displayed:
Do you want to create this table entry? (Yes or No):
12. Type Y to create a new table entry, or type N to cancel the entry.
13. From the Main Menu, select System Configuration.
The System Configuration Menu is displayed, as shown in Figure 10
on page 46.