13. Do not strip more than the recommended amount of wire. Stripping more than the recommended
amount can create a safety hazard by leaving exposed wire on the terminal block after installation.
14. When installing this equipment, always ensure that the frame ground connection is installed first and
disconnected last.
15. Check to see if there are any exposed copper strands coming from the installed wire. When this
installation is done correctly there should be no exposed copper wire strands extending from the terminal
block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires.
17. This system works with positive grounded or negative grounded DC systems.
18. Only trained and qualified personnel are allowed to install or to replace this equipment.
19. The attached mounting brackets must be used to securely mount the device on the wall.
20. Do not install in direct sunlight, or a damp or dusty place.
21. Do not expose the gateway device to moisture or water.
22. If the gateway device is installed indoors, make sure that the site is a dust free environment. The site
should provide for easy access to the ports of the gateway device.This will make it easy for you to connect
and disconnect cables, as well as view the LEDs.