Testing Ethernet LAN Ports
A crossover cable is required to run an Ethernet LAN test. How to make a
suitable cable is described in “Cables for RJ-45 Ethernet LAN Interfaces” on
page 31. To start the test, loop a four-pair crossover or straight-through cable
between two RJ-45 ports and enter the enable test interface=all command.
Interfaces connected by crossover cables are tested. If a test fails, contact your
authorised distributor or reseller.
To display test results, use the show test command. To display detailed output
with frame counts, use the show test count command. For example output
from these commands, see the Test Facility chapter in the Software Reference.
This chapter also contains information on how to test other interfaces.
Diagnostics
Software for the x900 Series switch includes a set of diagnostic programs that
perform basic checks of all system components. These diagnostics do not run
with normal operating code and require that the system be totally dedicated to
their use. The switch does not perform switching operations when diagnostics
are running.
Caution Diagnostics are designed to be run by service personnel only. This
section is not intended as a guide to diagnostics software. Detailed knowledge
of how the switch hardware functions is necessary in order to effectively use
diagnostic programs. For more information, contact your authorised distributor
or reseller.
Enabling
diagnostics mode
1. Connect a terminal to the RS-232 terminal port (ASYN0).
Use a terminal cable to connect a terminal to the RS-232 port (ASYN0) on
the switch. For more information on terminal cables, see “RS-232 Terminal
and Modem Cables” on page 30.
Set the terminal communication parameters as follows:
•Baud rate: 9600
Data bits: 8
•Parity: None
Stop bits: 1
•Flow control: Hardware
For more information, see “Using Windows Terminal and HyperTerminal
on page 16.
2. Restart the switch.
To restart the switch, use a small diameter pin to press the recessed Reset
button on the front panel of the switch. You can also log in at the terminal
and enter the command:
restart reboot
How to log in is described in the Installation and Safety Guide.
3. Enable diagnostics mode during self-tests at startup.
The switch pauses briefly during its self-tests to allow an override.
For AT-8948, x900-48FE, and AT-9900 switches, the following prompt is
displayed:
Force EPROM download (Y)?