Features in 291-17 10
Version 291-19
C613-10488-00 REV R
Features in 291-17
Software Maintenance Version 291-17 includes the resolved issues and enhancements in the following tables. In the tables, for each product series:
“Y” indicates that the resolution is available in Version 291-17 for that product series.
” indicates that the issue did not apply to that product series.
Level 1
No level 1 issues.
Level 2
CR Module Level Description
AR44x / AR450
AR7x5
AR750S / AR770S
Rapier i
Rapier w
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800
CR00020173 X.25 2 The router or switch could restart unexpectedly when three or more X.25T
circuits were all transmitting. This issue has been resolved.
As well, the router or switch will now ensure that X.25 calls are cleared
when installed in a X.25 network that sends Reset Indications in response
to Reset Confirmation messages. Sometimes when an X25 network resets
a circuit with a Reset Indication the network is not satisfied by a Reset
Confirmation reply and continues to send a Reset Indication for every Reset
Confirmation. The router or switch now counts the Reset Indications
received and clears the call if more than 3 Reset Indications are received
with no data transferred between them.
YYYYY–